Floor standing Shaker incubator combines incubator and shaker functions together, it uses new outlook design with big touch screen,. Adopt the latest technology of motor driven system, large torque, stable work, low noise and fast heat dissipation and long lifetime. It is widely used Cell culture, fermentation, biochemistry, enzyme research experiment or medium production experiment. Especially suitable for medium production, it solves the user’s problem by advanced design and high precise manufacturing art craft.
With “C” means the model with refrigeration function Max. triangular flask clips can be placed (single layer)
Model
BSI-21
BSI-31
BSI-21C
BSI-31C
Power supplies
AC220V 50HZ
AC220V 50HZ
AC220V 50HZ
AC220V 50HZ
Shake frequency
40~300rpm
40~300rpm
40~300rpm
40~300rpm
Amplitude
26mm
26mm
26mm
26mm
Control temp. range
RT+5~80℃
RT+5~80℃
4~80℃
4~80℃
Temp. resolution
0.1°C
0.1°C
0.1°C
0.1°C
Timer range
1-99h59min
1-99h59min
1-99h59min
1-99h59min
Rated Power
1050W
1050W
51300W
1300W
Shelves size (mm)
750×460
920×500
750×460
920×500
Overall size W×D×H
(mm)1060×680×910
1200×730×930
1060×680×910
1200×730×930
Standard configuration
250ml×28
250ml×45
250ml×28
250ml×45
Model capacity
BSI-21
BSI-21CBSI-31
BSI-31C
50 ml
82
116
100 ml
50
66
250 ml
28
45
500 ml
23
28
1000 ml
15
18
2000 ml
8
13
● User’s set parameters can be stored automatically when power off suddenly, and it resume last program settings when power on.
● PID microcomputer control temp. and shake frequency with timer.
● Compressor and cycle fan etc key components are reliable suppliers, environmental non-free refrigerantsUninterrupted performance guaranty
● Brushless DC motor, large start torque, wide speed adjustment, free maintenance.
● Protection on instruments: Comply international standard secondary temp. limiter alarm system, alert the operator with sound and light alarms, ensure operator is safe without any accident.
● Protection on key components: Key components have over current, over temp., over load etc safety protection, it can prevent instruments accidents without precautions.
● Protection on samples: Working chamber temperature higher or lower the set temp., alarm starter cut down the heater, alert the operator with sound and light alarms.
● Breakdown message provided: When the instrument breakdown, the breakdown messages show on the screen to help operator easily check.Three-eccentric axis balance drive
● Three-eccentric axis balance drive ensures all samples in the shaker platform movements at the same rotation frequency. Durable structure guarantees the shaker incubator can work properly no matter full load or high speed working.Multi-segment programmable control
● Multi-segment temp., speed, time program at the same time. It has normal mode or programmable mode for running. Preset parameter and work data can be shown at the same time. It simplified complicated culture requirements and realize auto control and run.Feature extension(Option)
● CO2 concentration monitor and control
● Lighting control(Stimulate the nature growth environment)
● Humidity monitor and control